Lexa Mini sterilizer, 3 liters
Sterilizer supplied with 2 aluminum trays, drain hose, tray holder, 8 GB USB drive, door opening tool, factory test, compressed air tube (for compressed air models only),
50/60 HzLexa Mini RIS-303 (220 V)
REF 19944110Chamber size 3 liter, compressed air
Lexa Mini RIS-303 (110 V)
REF 19944210Chamber size 3 liter, compressed air
Lexa Mini sterilizer, 5 liters
Sterilizer supplied with 2 aluminum trays, drain hose, tray holder, 8 GB USB drive, door opening tool, factory test, compressed air tube (for compressed air models only),
50/60 HzLexa Mini RIS-305 (220 V)
REF 19945110Chamber size 5 liter, compressed air
Lexa Mini RIS-305 (220 V)
REF 19935112Chamber size 5 liter, vacuum pump
Lexa Mini RIS-305 (110 V)
REF 19945210Chamber size 5 liter, compressed air
Lexa Mini RIS-305 (110 V)
REF 19935212Chamber size 5 liter, vacuum pump
Download Area
FAQs
-
What is validation?
Validation is a testing procedure carried out by an official authority, proving the effectiveness of your sterilizer. Compulsories and frequency of validation are regulated by local/national guidelines. more
-
Do I need to document the results of all periodic tests?
W&H recommends recording all periodic tests, repairs and modifications on the sterilizer in a logbook including date and signature of the person who carried out the test or other activity. Compulsoriness of recording is regulated by local/national guidelines. more
-
How long should I archive the documentation of regular tests?
Keep the results according to your country/regional specific laws and guidelines. Those records can be of assistance in case of service as well. more
-
Does my sterilizer need any periodic qualification/validation?
Validation generally comprises a range of tests defined in internationally recognised standards. These tests begin for every device with the factory tests at W&H. In addition, corresponding documentation is included with your device. Prior to commissioning the device at your premises, the technician performs further checks to ensure the device functions correctly. Then, depending on the national/regional laws and directives, the device must be subjected to a so-called renewed performance qualification at regular intervals. For further information, please contact your dealer. more
-
Whom should I contact to validate and maintain my sterilizer?
Validation shall be carried out by an official authority. Maintenance tasks shall be carried out by a qualified and authorized technician. more
-
Should I pouch wrap my instruments and how long can I store them after sterilization?
To ensure that your instruments are stored in a sterile state from their successful sterilization until they are used, W&H recommends wrapping them in suitable sterile barrier systems before sterilization. The recommended storage period can be found in the recommendations of the wrapping material manufacturer. For further information, please contact your dealer. more
-
Which water quality should I use for my Lexa Plus sterilizer?
The water quality for sterilizers is internationally specified by standards and directives. The reasons for this are that your sterilizer can be seriously damaged by it or the sterilization can be jeopardised. Consequently, only water with conductivity of less than 10 µS/cm in North America and 15 µS/cm for the rest of the world should be used for your W&H sterilizer. The Multidem system and OSMO are especially designed to prepare suitable water (see chapter “Water quality” in the Instructions for Use). more
-
Do I need to carry out periodic testing on my W&H Sterilizer?
All W&H sterilizers features test cycles (B&D/Helix test, Vacuum test). Compulsory and frequency of testing are regulated by local/national guidelines. more
-
How do I clean the water tank and what products should I use?
Water tank cleaning instructions are provided in the Instructions for Use, chapter “Maintenance”. In addition, a video description is available: • in the sterilizer, in the maintenance section of the menu. more
-
What is the maximum noise level of the Lisa Mini sterilizer?
The max. noise level of Lisa Mini is 64 dB. more
-
How do I change consumable components on my sterilizer?
Consumable replacement instructions are provided in the Instructions for Use, chapter “Maintenance”. In addition, a video description is available: • in the sterilizer, in the maintenance section of the menu. more
Instructions for use
Find all languages of the Update Hygiene and Maintenance (EN ISO 17664:2017) in the Download Centre.
Video Tutorials
-
What is validation?
-
Lexa Mini sterilization cycles
Sterilization cycle: Wrapped Low Temperature Unwrapped Temperature: 270°F 270°F 270°F Sterilization time: 4 min 30 min 4 min Total cycle duration
(minutes)
complete drying time:3 liter (compressed air) 23 min–25 min 47 min–50 min 30 sec
13 min–15 min 5 liter (compressed air) 23 min 30 sec–27 min 48 min–57 min 13 min 30 sec–17 min 5 liter (vacuum pump) 25 min 30 sec–29 min 49 min 30 sec–58 min 14 min–17 min 30 sec Max load: 2.2 lbs. (3 liter) / 3.3 lbs (5 liter) wrapped and unwrapped 2.2 lbs. (3 liter) / 3.3 lbs (5 liter) unwrapped Sterilizer supplied with 2 aluminum trays, drain hose, tray holder, 8 GB USB drive, door opening tool, factory test, compressed air tube
(for compressed air models only).Meets the requirements of ASME Boiler and Pressure Vessel Code Lexa Mini
Trade name:
Type:Lexa Mini
RIS-303Lexa Mini
RIS-305Lexa Mini
RIS-305Chamber size: 3 liters (compressed air) 5 liters (compressed air) 5 liters (vacuum pump) Power supply: 200–240 V AC; 50/60 Hz; 10 A single phase
100-125 V AC; 50/60 Hz; 12 A single phasePower consumption: 2.0–2.4 kW (220 V)/1.2-1.5 kW (110V) Overall dimension (w × h × d): 17.3” × 7.9” × 22.9”
(440 mm × 200 mm × 581 mm)17.3” × 7.9” × 26.2”
(440 mm × 200 mm × 666 mm)17.3” × 7.9” × 26.2”
(440 mm × 200 mm × 666mm)Weight (empty): 48.3 lbs (21.9 kg) 53.8 lbs (24.4 kg) 53.8 lbs (24.4 kg) Main/used water tanks: 0.42 gal/0.16 gal 0.67 gal/0.16 gal 0.67 gal/0.16 gal Working range: 3 to 7 cycles Average air consumption: 50–60 (N)l/min (13.2–15.8 (N)gal/min) n/a Working pressure: 5–10 bar (73–145 psi) n/a Connection types: 5 USB ports, 1 Ethernet (LAN) port, automatic water filling kit and drain kit Lexa Mini sterilizers were designed, certified and validated with the most stringent directives and standards: EN 13060
Small steam sterilizers2014/68/EU
Pressure Equipment DirectiveIEC 61010-2-040
Safety specific requirements for steam sterilizersANSUAAMI ST55
Table-top steam sterilizersCSA-C22.2 No 61010-1
Safety requirements for electrical equipment for measurement, control and laboratory use, general requirementsIEC 61770
Electric appliances connected to the water mains (avoidance of backsiphonage)N°2017/745
Medical Device RegulationIEC 61326-1
Electromagnetic compatibility2012/19/EU
Waste Electrical and Electronic Equipment (WEEE)UL 61010-1
Safety requirements for electrical equipment for measurement, control and laboratory use, general requirements> The sterilizer can be validated according to EN ISO 17665-1